Bullard 30 CFM Clean Air Box, 2 Outlet
Overview
Bullard Clean Air Boxes (CAB) offer 3-stage filtration with carbon monoxide (CO) monitoring to comply with OSHA’s requirement for providing workers with Grade D breathing air. Three stages of filtration remove oil, water, particulate, oil vapor and odors. Designed for 2 users.
Details
High Performance Air Filtering and Monitoring. Bullard Clean Air Box (CAB) Systems can help employers comply with Grade D breathing standards by providing high performance particulate filtration and continuous CO monitoring with auto calibration. CABs also feature high performance three-stage filtration, auto-drains, filter change indicators, and audible and visual alarms for high CO and low battery. CAB systems require a compressed air system and adequate air volume capacity.
Three-Stage Filtration
Three stages of filtration remove oil, water, particulate, oil vapor and odors.
- First Stage - Removes solid contaminants and bulk liquids from the breathing air, down to five microns, prolonging the life of the second and third stage elements.
- Second Stage - Removes extremely fine oil mists down to .01 microns. The maximum remaining filter efficiency is 99.9998%.
- Third Stage - Removes unpleasant oil and hydrocarbon vapors and odors from the air. The maximum remaining oil content is .003 ppm by weight. Filter efficiency is 99.9998%.
Features
- Automatic condensate drains extend filter element life
- Filter change indicators visually alerts the operator to replace element
- CO Monitor with auto calibration takes approximately 90 seconds and requires no tools
- Audible and visual alarms for high CO, low airflow and low battery
- High intensity 90 dB alarm remote capable with strobe
- Includes 2 outlets
- Rugged polycarbonate case
Fresh air hoses, masks, lens covers etc. sold separately.